Endress+Hauser Absolute and Gauge Pressure Cerabar PMP51

Digital pressure transmitter with welded metal sensor for measurement in gases, steam or liquids.

Free shipping
Credit Card

Overview

The Cerabar PMP51 digital pressure transmitter with metal membrane is typically used in process and hygiene applications for pressure, level, volume or mass measurement in liquids or gases. PMP51 is designed for high pressure applications up to 400bar. Quick Setup with adjustable measuring range allows simple commissioning, reduces costs and saves time. SIL2 according to IEC 61508 and IEC 61511.


Benefits

  • Accurate measurement of the process value even in the case of changing process temperature

  • Process safety assured with small flush mounted process connections in hygienic applications

  • For process pressure monitoring up to SIL2, certified to IEC 61508 and IEC 61511

  • Modular concept for easy replacement of display or electronics

  • Easy menu-guided commissioning via on-site display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus

  • Seamless and independent system integration (HART/PA/FF)

  • Available with mounted manifolds: always fit, always tested for leaks


Application

Single chamber aluminum or stainless steel (316L) housing.

  • Process connections: Threads, flanges or hygienic connections

  • Process temperature: -40 to +130°C (-40 to +266°F), 150°C (302°F) for 1h

  • Measuring range: -1/0 up to +400bar (-15/0 up to +6,000psi)

  • Accuracy: ±0.15%, "Platinum" ±0.075%

  • International explosion protection certificates, SIL, hygienic approvals, marine approvals


Specification

Measuring PrincipleAbsolute and gauge pressure
CharacteristicSmart and reliable pressure transmitter, with piezoresistive measuring cell and metal welded process isolating diaphragm
Supply voltage4...20mA HART
11,5...45V DC (Non Ex):
Ex ia: 11,5...30V DC
PROFIBUS PA:
9...32 V DC (Non Ex)
FOUNDATION Fieldbus:
9...32 V DC (Non Ex)

Reference AccuracyStandard 0,15%
Platinum 0,075%
Long term stability< 0,1% of URL/year
0,2% of URL/ 5 years
0,25% of URL/ 10 years

Process temperature-40°C...130°C
(-40°F...266°F
150°C for 1h
(302°F for 1h)

Ambient temperature-40°C...85°C 
(-40°F...185°F)
Measuring cell400mbar...400bar
(15psi...6000psi)
relative/ absolute

Smallest calibratable span20 mbar (0.3 psi)
Vacuum resistance10 mbar (0.15 psi)

Max. Turn down20:1
Max. overpressure limit600bar (9000psi)
Process connectionThread:
G1/2...G2, MNPT1/2...MNPT2
Flange:
DN25...DN80,
ASME 1 1/2"...4",

Process connection hygienicTri-Clamp
DIN11851
NEUMO
Varivent N
SMS
DRD
Material process membrane316L, AlloyC,
Tantal,
Rhodium>Gold
Material gasketNone, measuring cell welded
Fill fluidSilicone oil,
Inert oil
Material housingDie-cast aluminum,
AISI 316L
Communication4...20 mA
4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / ApprovalsATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI

Safety approvalsSIL

Design approvalsEN10204-3.1
NACE MR0175

Hygienic approvals3A, EHEDG
CoC ASME-BPE

Marine approvalsGL/ ABS/ LR/ BV/ DNV

Drinking water approvalsNSF