Differential pressure transmitter with one diaphragm seal for level measurement.

Free shipping
Credit Card

Overview

The Deltabar FMD77 differential pressure transmitter with metal sensor uses a one-sided diaphragm seal or diaphragm seals on both sides with a capillary on the low pressure side. Typically used in the process industry for continuous level measurement in liquids. The integrated HistoROM data module makes the management of process and device parameters easy. Designed according to IEC 61508 for use in SIL3 safety applications.


Benefits

  • Large variety of different process connections and membrane materials

  • Highest safety due to gas-tight feedthrough with capabilities up to SIL2/3, certified to 
    IEC 61508

  • New TempC Membrane minimizes influences of ambient and process temperature fluctuations

  • Easy menu-guided commissioning via local display, 4 to 20 mA with HART, PROFIBUS PA, FOUNDATION Fieldbus

  • HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics

  • Cost savings with modular concept for easy replacement of sensor, display or electronics

  • Seamless and independent system integration (HART/PA/FF)


Application

For level, volume or mass measurement in liquids.

  • Process connections: Threads and flanges

  • Temperature: -70 to +400°C (-94 to +752°F)

  • Measuring ranges: +100mbar to +16bar (+1.5 to +240psi)

  • Accuracy: ±0.075%

  • International explosion protection certificates, overfill prevention WHG, hygienic approvals, marine approvals, SIL


Specification

Measuring PrincipleDifferential pressure
Characteristic / ApplicationDigital transmitter with metallic measuring diaphragms one side with diaphragm seal
Modular transmitter
Long term stability
Enhanced safety via self diagnostic functions
Secondary process barrier
Supply / Communication4...20 mA HART:
10,5...45V DC
Ex ia: 10,5...30V DC
PROFIBUS PA /
FOUNDATION Fieldbus:
9...32V DC
Accuracy0,075% + influence of diaphragm seal
Long term stability0,05% of URL/year
Ambient temperature-50°C...85°C
(-58°F...185°F)
Process temperature-40°C...400°C
(-40°F...752°F)
Process pressure absolute / max. overpressure limit160bar (2400 psi)
Pressure measuring range100mbar...16bar 
(1.5psi...230 psi)
Main wetted partsAlloy C276
316L
Monel
Tantalum
Process connectionLow pressure side:
1/4-18NPT
RC1/4"
High pressure side:
Flanges (DIN, ASME, JIS)
Max. measurement distance160m (525ft) H2O
Communication4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / ApprovalsATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI, EAC

Safety approvalsSIL

Design approvalsEN10204-3.1
NACE MR0175, MR0103

OptionsHistoROM/M-Dat
4-line digital display
SS- or Aluminiumhousing
Separate housing 

Application limitsMeasuring cell:
Metal welded