Unsurpassed reliability, accuracy and long-term stability in critical processes over all industries. The configurable transmitter not only transfers converted signals from resistance thermometers Endress Hauser(RTD) and thermocouples (TC), but also resistance and voltage signals using HART® communication. High measurement point availability by means of sensor monitoring functions. Diagnostics information according to NAMUR NE 107. Optimization of the measurement accuracy by sensor-transmitter matching.


Benefits

  • Certified up to SIL 2/3 - hardware/software - according to IEC 61508:2010

  • Safe operation in hazardous areas, international approvals such as FM IS, NI; CSA IS, NI; ATEX, NEPSI, IECEx Ex ia, Ex nA for intrinsically safe installation in zone 1 and zone 2;

    Marine approval

  • HART® 7 version

  • High accuracy of measuring point through sensor-transmitter matching

  • Reliable operation with sensor monitoring and device hardware fault recognition

  • Diagnostics information according to NAMUR NE107

  • Rapid no-tools wiring due to optional spring terminal technology;


Application

  • The device stands out due to signal reliability, long-term stability, high precision and advanced diagnostics (important in critical processes) 

  • For the highest level of safety, availability and risk reduction

  • Universal input for RTD, TC, resistance transmitters (Ω), voltage transmitters (mV)

  • Installation in flat-face terminal head as per DIN EN 50446

  • Optional installation in field housing even for use in Ex d applications 

  • Device design for DIN rail mounting optional


Features

Measuring PrincipleHead transmitter
Input2 x RTD, TC
Output1 x analog 4...20 mA / HART
Auxiliary power supply11...42 V DC
CommunicationHART-protocol
InstallationTerminal head form B or DIN-Rail housing
Accuracy(Pt100) <= 0,1K (digital) + 0,03% (set range)
Galvanic isolationyes
CertificationATEX II1G Ex ia IIC T4/T5/T6
ATEX II2D Ex tb IIIC Db
ATEX II3D Ex tc IIIC Dc
ATEX II3G Ex nA IIC T6
ATEX II1G Ex ia IIC T6, II3D
ATEX II3G Ex nA IIC T6, II3D
ATEX II2G Ex d T6, II2D Ex tb IIIC
CSA IS, NI I / 1+2/A-D
CSA XP, NI, DIP I, II, III/1+2/A-G
FM IS,NI I / 1+2/A-D
FM XP, NI, DIP I, II, III/1+2/A-G
IECEx Ex ia IIC T4/T5/T6
IECEx Ex tb IIIC Db
IECEx Ex d T6 Gb, Ex tb IIIC Db
NEPSI Ex ia IIC T4/T5/T6
NEPSI Ex nAL II T4/T5/T6
ATEX IECEx II1G Ex ia IIC T6 Ga
FM+CSA IS, NI I/1+2/A-D
EAC
Marine approval


Specification

Data Sheet