Prosonic Flow B 200 is the specialist for accurate and reliable measurement of wet biogas and digester gas,even under fluctuating process conditions. With its unique integrated real-time methane fraction analysis, Prosonic Flow B 200 enables continuous measurement and monitoring of gas flow as well as gas quality. In addition to efficient process control and energy balancing, Heartbeat Technology ensures compliance and process safety at all times.

Benefits

  • Integrated real-time methane fraction measurement

  • Optimized for low pressure gas – specialized sensor design

  • No additional pressure loss – full bore design

  • Process transparency – diagnostic capability

  • Convenient device wiring – separate connection compartment

  • Safe operation – no need to open the device due to display with touch control, background lighting

  • Integrated verification – Heartbeat Technology

Application

  • The measuring principle is unaffected by gas composition

  • Inline flowmeter designed for wet biogas and digester gas under fluctuating process conditions.

Device properties:

  • Multivariable device: flow, temperature and methane

  • Medium temperature: 0 to 80 °C (32 to 176 °F)

  • Process pressure: 0.7 to 11 bar a (10.2 to 159 psi a)

  • Loop-powered technology

  • Robust dual-compartment housing

  • Plant safety: worldwide approvals

Specification

Measuring PrincipleUltrasonic flow
Product headlineThe device for accurate, reliable biogas measurement with loop‐powered technology. Integrated real‐time methane fraction measurement. Inline flowmeter designed for wet biogas and digester gas under fluctuating process conditions.
Sensor featuresOptimized for low pressure gas – specialized sensor design. No additional pressure loss – full bore design. Process transparency – diagnostic capability. Multivariable device: flow, temperature and methane. Medium temperature: 0 to 80 °C (32 to 176 °F).
Transmitter featuresConvenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Loop‐powered technology. Robust dual-compartment housing.
Nominal diameter rangeSingle‐path version: DN 50 (2"), DN 80 (3")
Two‐path version: DN 100 to 200 (4 to 8")
Wetted materialsSensor: 1.4404/1.4435 (316L)
Transducer: HNBR 
Temperature sensor (option): AFM 34
Measured variablesVolume flow, corrected volume flow, corrected methane volume flow, energy flow, methane fraction, calorific value, temperature
Max. measured errorVolume flow (standard):
‐ ±1.5 % o.r. for 3 to 30 m/s (9.84 to 98.4 ft/s)
‐ ±3 % o.r. for 1 to 3 m/s (3.28 to 9.84 ft/s)
Volume flow (option):
‐ ±0.1 % o.f.s. for 0.3 to 1 m/s (0.98 to 3.28 ft/s)
‐ ±1.5 % o.r. for 1 to 30 m/s (3.28 to 98.4 ft/s)
Measuring rangeStandard: 1 to 30 m/s (3.28 to 98.4 ft/s)
Option: 0.3 to 30 m/s (0.98 to 98.4 ft/s)
Max. process pressure11 bar a (159 psi a)
Medium temperature range0 to +80 °C (+32 to +176 °F)
Ambient temperature rangeFlange material carbon steel: –10 to +60 °C (+14 to +140 °F)
Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)
Transmitter housing materialAlSi10Mg, coated; 1.4404 (316L)
Degree of protectionIP66/67, type 4X enclosure
Display/Operation4‐line backlit display with touch control
(operation from outside)
Configuration via local display and operating tools possible
Outputs4‐20 mA HART (passive)
4‐20 mA (passive) 
Pulse/frequency/switch output (passive)
InputsCurrent input 4‐20 mA (passive)
Digital communicationHART
Power supplyDC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
DC 12 to 30 V (4‐20 mA HART, 4‐20 mA)
DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input)
DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch Output)
Hazardous area approvalsATEX, IECEx, cCSAus, NEPSI, INMETRO, JPN
Metrological approvals and certificatesCalibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Pressure approvals and certificatesPED
Material certificates3.1 material (wetted parts)