Yokogawa Analog Insulation Tester 2406E Series (Multi Range)

Vendor: Yokogawa

Free shipping
Credit Card

Overview

  • Analog models with two and three rating
  • AC voltage measurement
  • Automatic discharge
  • Sky blue EL backlight
  • Increased safety (covered battery charger)

Specification

Model 240631

Rating125V/20M~
25V/5M~
50V/10M~
Effective Measuring Range0.001-5M~
0.005-10M~
0.01-20M~
Central Scale Value0.1M~
0.2M~
0.5M~
AC Voltage Measurement0 to 300 V
Lower Limit0.025M~
0.05M~
0.125~
Rated Current1 mA
Approx. Outer Scale Length88 mm
Discharge FunctionThe tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (&
Approx. Width120 mm
Approx. Height110 mm
Approx. Depth60 mm
Approx. Weight500 g
BatteriesSix AA (R6P) batteries
Standard AccessoriesBatteries (Qty- 6)
Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long
Earth probes and Line Probes (98007) (Qty - 1)
User's Manual (Qty - 1)- With probe-housing pocket and neck strap

 

Standard Test Conditions - Model 240631 

Ambient Temperature/Humidity Ranges23 ±5 /45-75% RH
Position of UseHorizontal (5º max. of angle of inclination)
External Magnetic FieldsNone Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)
Tolerance Mentioned ConditionsResistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading
Infinite and zero scale values: 0.7% max. of scale length
AC voltage: ±10% of maximum scale value
No-load voltage: 130% max. of rated voltage
Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range
Short-circuit current: 12 mA max.

 

Model 240641 

Rating125V/20M~
25V/5M~
50V/10M~
Effective Measuring Range0.001-5M~
0.005-10M~
0.01-20M~
Central Scale Value0.1M~
0.2M~
0.5M~
AC Voltage Measurement0 to 300 V
Lower Limit0.025M~
0.05M~
0.125~
Rated Current1 mA
Approx. Outer Scale Length88 mm
Discharge FunctionThe tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (&
Approx. Width120 mm
Approx. Height110 mm
Approx. Depth60 mm
Approx. Weight500 g
BatteriesSix AA (R6P) batteries
Standard AccessoriesBatteries (Qty- 6)
Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long
Earth probes and Line Probes (98007) (Qty - 1)
User's Manual (Qty - 1)- With probe-housing pocket and neck strap

 

Standard Test Conditions - Model 240641 

Ambient Temperature/Humidity Ranges23 ±5 /45-75% RH
Position of UseHorizontal (5º max. of angle of inclination)
External Magnetic FieldsNone Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)
Tolerance Mentioned ConditionsResistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading
Infinite and zero scale values: 0.7% max. of scale length
AC voltage: ±10% of maximum scale value
No-load voltage: 130% max. of rated voltage
Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range
Short-circuit current: 12 mA max.

 

Model 240632 

Rating125V/20M~
Effective Measuring Range0.01-20M~
Central Scale Value0.5M~
AC Voltage Measurement0 to 300 V
Lower Limit0.125~
Rated Current1 mA
Approx. Outer Scale Length88 mm
Discharge FunctionThe tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (&
Approx. Width120 mm
Approx. Height110 mm
Approx. Depth60 mm
Approx. Weight500 g
BatteriesSix AA (R6P) batteries
Standard AccessoriesBatteries (Qty- 6)
Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long
Earth probes and Line Probes (98007) (Qty - 1)
User's Manual (Qty - 1)- With probe-housing pocket and neck strap

 

Standard Test Condtions - Model 240632 

Ambient Temperature/Humidity Ranges23 ±5 /45-75% RH
Position of UseHorizontal (5º max. of angle of inclination)
External Magnetic FieldsNone Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)
Tolerance Mentioned ConditionsResistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading
Infinite and zero scale values: 0.7% max. of scale length
AC voltage: ±10% of maximum scale value
No-load voltage: 130% max. of rated voltage
Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range
Short-circuit current: 12 mA max.

 

Model 240642 

Rating250V/50M~
Effective Measuring Range0.01-50M~
Central Scale Value1M~
AC Voltage Measurement0 to 300 V
Lower Limit0.25~
Rated Current1 mA
Approx. Outer Scale Length88 mm
Discharge FunctionThe tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (&
Approx. Width120 mm
Approx. Height110 mm
Approx. Depth60 mm
Approx. Weight500 g
BatteriesSix AA (R6P) batteries
Standard AccessoriesBatteries (Qty- 6)
Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long
Earth probes and Line Probes (98007) (Qty - 1)
User's Manual (Qty - 1)- With probe-housing pocket and neck strap

 

Standard Test Conditions - Model 240642 

Ambient Temperature/Humidity Ranges23 ±5 /45-75% RH
Position of UseHorizontal (5º max. of angle of inclination)
External Magnetic FieldsNone Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)
Tolerance Mentioned ConditionsResistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading
Infinite and zero scale values: 0.7% max. of scale length
AC voltage: ±10% of maximum scale value
No-load voltage: 130% max. of rated voltage
Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range
Short-circuit current: 12 mA max.

 

Model 240633 

Rating125V/20M~
250V/50M~
500V/100M~
Effective Measuring Range0.01-20M~
0.01-50M~
0.05-100M~
Central Scale Value0.5M~
1M~
2M~
AC Voltage Measurement0 to 600 V
Lower Limit0.125M~
0.25M~
0.5~
Rated Current1 mA
Approx. Outer Scale Length88 mm
Discharge FunctionThe tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (&
Approx. Width120 mm
Approx. Height110 mm
Approx. Depth60 mm
Approx. Weight500 g
BatteriesSix AA (R6P) batteries
Standard AccessoriesBatteries (Qty- 6)
Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long
Earth probes and Line Probes (98007) (Qty - 1)
User's Manual (Qty - 1)- With probe-housing pocket and neck strap

 

Standard Test Conditions - Model 240633 

Ambient Temperature/Humidity Ranges23 ±5 /45-75% RH
Position of UseHorizontal (5º max. of angle of inclination)
External Magnetic FieldsNone Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)
Tolerance Mentioned ConditionsResistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading
Infinite and zero scale values: 0.7% max. of scale length
AC voltage: ±10% of maximum scale value
No-load voltage: 130% max. of rated voltage
Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range
Short-circuit current: 12 mA max.

 

Model 240343 

Rating125V/20M~
250V/50M~
500V/100M~
Effective Measuring Range0.01-20M~
0.01-50M~
0.05-100M~
Central Scale Value0.5M~
1M~
2M~
AC Voltage Measurement0 to 600 V
Lower Limit0.125M~
0.25M~
0.5~
Rated Current1 mA
Approx. Outer Scale Length88 mm
Discharge FunctionThe tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (&
Approx. Width120 mm
Approx. Height110 mm
Approx. Depth60 mm
Approx. Weight500 g
BatteriesSix AA (R6P) batteries
Standard AccessoriesBatteries (Qty- 6)
Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long
Earth probes and Line Probes (98007) (Qty - 1)
User's Manual (Qty - 1)- With probe-housing pocket and neck strap

 

Standard Test Conditions - Model 240643 

Ambient Temperature/Humidity Ranges23 ±5 /45-75% RH
Position of UseHorizontal (5º max. of angle of inclination)
External Magnetic FieldsNone Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)
Tolerance Mentioned ConditionsResistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading
Infinite and zero scale values: 0.7% max. of scale length
AC voltage: ±10% of maximum scale value
No-load voltage: 130% max. of rated voltage
Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range
Short-circuit current: 12 mA max.

 

Model 240634 

Rating1000V/2000M~
250V/50M~
500V/100M~
Effective Measuring Range0.01-50M~
0.05-100M~
1-2000M~
Central Scale Value1M~
2M~
50M~
AC Voltage Measurement0 to 600 V
Lower Limit0.25M~
0.5M~
1~
Rated Current1 mA
Approx. Outer Scale Length88 mm
Discharge FunctionThe tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (&
Approx. Width120 mm
Approx. Height110 mm
Approx. Depth60 mm
Approx. Weight500 g
BatteriesSix AA (R6P) batteries
Standard AccessoriesBatteries (Qty- 6)
Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long
Earth probes and Line Probes (98007) (Qty - 1)
User's Manual (Qty - 1)- With probe-housing pocket and neck strap

 

Standard Test Condtions - Model 240634 

Ambient Temperature/Humidity Ranges23 ±5 /45-75% RH
Position of UseHorizontal (5º max. of angle of inclination)
External Magnetic FieldsNone Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)
Tolerance Mentioned ConditionsResistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading
Infinite and zero scale values: 0.7% max. of scale length
AC voltage: ±10% of maximum scale value
No-load voltage: 130% max. of rated voltage
Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range
Short-circuit current: 12 mA max.

 

Model 240644

Rating1000V/2000M~
250V/50M~
500V/100M~
Effective Measuring Range0.01-50M~
0.05-100M~
1-2000M~
Central Scale Value1M~
2M~
50M~
AC Voltage Measurement0 to 600 V
Lower Limit0.25M~
0.5M~
1~
Rated Current1 mA
Approx. Outer Scale Length88 mm
Discharge FunctionThe tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (&
Approx. Width120 mm
Approx. Height110 mm
Approx. Depth60 mm
Approx. Weight500 g
BatteriesSix AA (R6P) batteries
Standard AccessoriesBatteries (Qty- 6)
Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long
Earth probes and Line Probes (98007) (Qty - 1)
User's Manual (Qty - 1)- With probe-housing pocket and neck strap

 

Standard Test Conditions - Model 240644 

Ambient Temperature/Humidity Ranges23 ±5 /45-75% RH
Position of UseHorizontal (5º max. of angle of inclination)
External Magnetic FieldsNone Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)
Tolerance Mentioned ConditionsResistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading
Infinite and zero scale values: 0.7% max. of scale length
AC voltage: ±10% of maximum scale value
No-load voltage: 130% max. of rated voltage
Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range
Short-circuit current: 12 mA max.

 

Specifications - Model 240635

 

Rating1000V/2000M~
250V/500M~
500V/1000M~
Effective Measuring Range0.1-500M~
0.5-1000M~
1-2000M~
Central Scale Value10M~
20M~
50M~
AC Voltage Measurement0 to 600 V
Lower Limit0.25M~
0.5M~
1~
Rated Current1 mA
Approx. Outer Scale Length88 mm
Discharge FunctionThe tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (&
Approx. Width120 mm
Approx. Height110 mm
Approx. Depth60 mm
Approx. Weight500 g
BatteriesSix AA (R6P) batteries
Standard AccessoriesBatteries (Qty- 6)
Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long
Earth probes and Line Probes (98007) (Qty - 1)
User's Manual (Qty - 1)- With probe-housing pocket and neck strap

 

Standard Test Conditions - Model 240635 

Ambient Temperature/Humidity Ranges23 ±5 /45-75% RH
Position of UseHorizontal (5º max. of angle of inclination)
External Magnetic FieldsNone Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)
Tolerance Mentioned ConditionsResistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading
Infinite and zero scale values: 0.7% max. of scale length
AC voltage: ±10% of maximum scale value
No-load voltage: 130% max. of rated voltage
Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range
Short-circuit current: 12 mA max.

 

Model 240645 

Rating1000V/2000M~
250V/500M~
500V/1000M~
Effective Measuring Range0.1-500M~
0.5-1000M~
1-2000M~
Central Scale Value10M~
20M~
50M~
AC Voltage Measurement0 to 600 V
Lower Limit0.25M~
0.5M~
1~
Rated Current1 mA
Approx. Outer Scale Length88 mm
Discharge FunctionThe tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (&
Approx. Width120 mm
Approx. Height110 mm
Approx. Depth60 mm
Approx. Weight500 g
BatteriesSix AA (R6P) batteries
Standard AccessoriesBatteries (Qty- 6)
Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long
Earth probes and Line Probes (98007) (Qty - 1)
User's Manual (Qty - 1)- With probe-housing pocket and neck strap

 

Standard Test Conditions - Model 240645 

Ambient Temperature/Humidity Ranges23 ±5 /45-75% RH
Position of UseHorizontal (5º max. of angle of inclination)
External Magnetic FieldsNone Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)
Tolerance Mentioned ConditionsResistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length
AC voltage: ±10% of maximum scale value
No-load voltage: 130% max. of rated voltage
Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range
Short-circuit current: 12 mA max.